Sign In | Join Free | My himfr.com
Home > Thermocouple Bare Wire >

E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use

Shanghai Tankii Alloy Material Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers
     
    Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers
    • Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers
    • Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers
    • Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers
    • Buy cheap E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use from wholesalers

    E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use

    Ask Lasest Price
    Brand Name : Tankii
    Model Number : E
    Certification : ISO9001
    Price : Negotiation
    Payment Terms : T/T, Paypal, Western Union, MoneyGram,
    Supply Ability : 1000Ton per year
    Delivery Time : 5-7 days after getting the payment
    • Product Details
    • Company Profile

    E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use

    Tankii Brand E Type Thermocouple Wires With Nichrome And Constantan Wire Used For Thermocouple Sensor


    The Type E thermocouple is composed of a nickel-10% chromium (+) versus a nickel-45% copper (-) wire. This Type of thermocouple can be used in oxidizing or inert atmospheres with a service temperature range of -200°C to 900°C (330°F to 1600°F). The Type E thermocouple can be used successfully in subzero applications due to high corrosion resistance to high moisture environments. Out of all of the different types of thermocouples, The Type E has the highest EMF output per degree.


    Application Range of Tankii thermocouple wire:
    1. Aerospace and Composites
    2. Aluminum industry
    3. Food and Pharmaceutical
    4. Forgings
    5. Glass, Ceramics, Clay Tiles, Bricks
    6. Heat Treating
    7. Petroleum, Downhole Oil & Gas
    8. Sensor Manufacturing

    Tankii Brand E Type Thermocouple Wires With Nichrome And Constantan Wire Used For Thermocouple Sensor


    Shanghai Tankii Thermocouple wire's Characteristics:
    The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.

    Tankii products conform to the standards of IEC584 -1and IEC-2.

    Tankii Thermocouple strips, thermocouple connectors are available.
    Tankii thermocouple grade extension wire can be supplied as per your request.
    Tankii KX, JX, TX KC, RC,EX wire with class 1 and 2 are available.
    Tankii Brand E Type Thermocouple Wires With Nichrome And Constantan Wire Used For Thermocouple Sensor
    More parameters of Tankii thermocouple wires:
    Tankii Thermocouple Type and Temperature Range

    Thermocouple type and index

    Measurement Range

    Type

    Index


    PtRh30-PtRh6

    B600~1700


    PtRh13-Pt

    R0~1600


    PtRh10-Pt

    S0~1600


    NiCr-NiSi

    K-200~1300


    NiCr-CuNi (constantan)

    E-200~900


    Fe-CuNi (constantan)

    J-40~750


    Cu-CuNi (constantan)

    T-200~350


    NiCrSi-NiSi

    N-200~1300

    The allowable grade and Tolerance are obtained at 0℃

    Thermocouple
    Type

    Grade

    Temperature range

    Allowable Tolerance /℃
    Type B600~1700±0.25% t
    600~800±4
    800~1700±0.5%t
    Type R(S)0~1100±1
    1100~1600±[1+(t-1100) ×0.3%]
    0~600±1.5
    600~1600±0.25% t
    Type K and Type N-40~1100±1.5℃ or ±0.4%t
    -40~1300±2.5℃ or ±0.75%t
    -200~40±2.5℃ or ±1.5%t
    Type E-40~1100±1.5℃ or ±0.4%t
    -40~1300±2.5℃ or ±0.75%t
    -200~40±2.5℃ or ±1.5%t
    Type J-40~750±1.5℃ or ±0.4%t
    -40~750±2.5℃ or ±0.75%t
    Type T-40~350±0.5℃ or ±0.4%t
    -40~350±1.0℃ or ±0.75%t
    -200~40±1.0℃ or ±1.5%t


    Product details:


    Delivery and Packing of thermocouple wire:
    1. Packaging Details : DIN spools with plastic film wrapped and carton package.
    2. Leading time : 5 - 20 days, as the order quantity of thermocouple wire.
    3. Delivery: By express, air, sea as per thermocouple wire qty
    Tankii Brand E Type Thermocouple Wires With Nichrome And Constantan Wire Used For Thermocouple Sensor
    Welcome to call me or email to me for more information on K type thermocouple wire, Thermocouple stranded wire , thermocouple flat wire, thermocouple strip.
    Quality E Type Thermocouple Wires With Nichrome And Constantan Wire Thermocouple Sensor Use for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Tankii Alloy Material Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)